Revision 1
38
Product Manual PSH-30 series Hand Wash Dryer
F80
Operation Counter
(Note 6)
0
9999
1
Press and Hold Select to
Reset. (X 100 Operations)
n/a
n/a
n/a
n/a
n/a
F95
Liquid Pump Iterations
1
20
1
(Note 7)
1
1
1
1
1
F100
Foam Pump Iterations
1
20
1
(Note 7)
1
1
1
1
1
F134
Soap Counter
X 100 Operations.
F135
Fan Counter
Fan Usage in Hours.
F145
Soap Warning LED Colour
0
8
1
1
1
1
1
1
F146
Soap Counter Warning Level
0
250
1
X 100 Operations.
0
0
0
0
0
F147
Soap Warning LED Pulses
1
5
1
1
1
1
1
1
F148
Soap Counter Reset on Prime
0
1
1
1
1
1
1
1
F149
Auto Water Off
0
100
10
(Note 9)
0
0
0
0
0
F151
Hot Air Enable
Off
On
Enable heater output
with fan
Off
Off
Off
Off
Off
F154 Drinking Water Run Time
Off
100 1
Seconds. Run time for
drinking water
10
10
10
10
10
F155 Drinking Water Start/Stop
Off
On 1
Press to start, press
again to stop
Off
Off
Off
Off
Off
F156 Drinking water L.O. Activations
Off
100 1
Limit of activations
allowed in cycle period
10
10
10
10
10
F157 Drinking water L.O. Cycle Period
0
250 1
Period during which
the activations are
allowed
60
60
60
60
60
F158 Drinking water L.O. Lockout
Period
0
250 1
Period of lockout when
activations are
exceeded
30
30
30
30
30
F159 Water Heater Delay On
0.0
5.0 0.1
Period of water flow
before water heater
turns on (Note 11)
0.0
0.0 0.0 0.0 0.5