Revision 1
31
Product Manual PSH-30 series Hand Wash Dryer
8.2. Advanced Adjustment
The unit is supplied with factory settings as shown in figure 31 below. Further
adjustments can be made to the configuration of the water, soap and air operations,
cycle sequence and the IR sensor trigger or activation length.
Warning! Incorrect alterations to the default hand wash settings may result in
malfunctions or possible unit damage.
If in any doubt,
contact “Wallgate after-sales service” for advice & information.
Figure 31: Settings table
Figure 24 F-Functions table for Water, Dryer and Soap times (shown in order of
operation) & auto cancel function.
1. To change the settings, you will need to enter the programming mode,
press and hold ‘MENU’ and ‘ENTER’ buttons simultaneously for 5 seconds
see figure 23. After this period,
the display will read ‘F 01’.
Description
Factory
Settings
Setting range
Function
Min.
Max
Increment
Soap dosage liquid/foam 0.4 sec
0.1
10
0.1
F 8
Delay Time
1 sec
1
10
0.1
F 10
Water Time
10 sec
1
100
1
F 04
Dryer Time
45 sec
1
100
1
F 06
End of cycle delay Time
3 sec
1
10
0.1
F 11
Water cycle auto cancel
¹
0 sec
0
10
1
F149
Hand drier auto cancel ¹
2 sec
0
10
1
F71
Set to zero to disable the auto cancel function.
Handwash Lockout
Activations
1
off
100
1
F84
Handwash Lockout Cycle
Period
20mins
0
250
1 minute
F85
Handwash Lockout Disable
Period
20mins
0
250
1 minute
F86
Drinking water L.O.
Activations
1
off
100
1
F156
Drinking water L.O. Cycle
Period
20mins
0
250
1 minute
F157
Drinking water L.O. Lockout
Period
20mins
0
250
1 minute
F158