90 t / 800 t
490527A
- 73 -
1. ~ 5 °C (~ 41 °F)
2. ~ 11 °C (~ 52 °F)
3. ~ 17 °C (~ 63 °F)
4. ~ 23 °C (~ 73 °F)
5. ~ 29 °C (~ 84 °F)
6. ~ 35 °C (~ 95 °F)
Operation
en
Normal Use
The power is adjusted manually. The cooker will always ignite in manual mode.
After the ignition power can be adjusted step-less with the power control (2) knob.
Avoid turning the power control knob rapidly back and forth, this may cause the
burner to become sooty.
Cooker used as a heater, thermostat use
Requires a heat blower lid (accessory).
Automatic power adjustment, thermostat controlled adjustment.
Is used only with a heat blower lid when the lid is folded over the ceramic top.
The function can be activated/deactivated whenever wanted. Turn the power cont-
rol knob (2) to positions min-max-min-max when yellow heating indicator (6) is on,
to activate the function. As a confirmation of the mode change, the thermostat light
(4) will be lit.
When turning again the power control knob (2) min-max-min-max, the thermostat
light (4) will go off and the unit returns to manual mode.
After the cooker has passed the ignition phase, the temperature is adjusted by
turning the power control knob (2). The power control knob is turned to the required
position.
When the thermostat light (4) is bright, the temperature is below the required tem-
perature – the effect is increased. When the thermostat light (4) dims the required
temperature is achieved.
The sun-switch shuts down the device automatically, if the temperature rises above
the requested temperature, for example, due to sunlight. The temperature must
rise by +3 °C above the set value for a half an hour. If the device has been shut
down by the sun-switch, an indicator light (4) blinks on the thermostat. The sun-
switch can be turned off temporarily, by turning the temperature control (2).
A device that has been shut down can be restarted manually, if necessary.
Conservation temperature: the temperature control (2) is set to minimum ,and
the room is maintained at a temperature of +2–+8 °C. The sun-switch is not ena-
The sun-switch is not ena-
The sun-switch is not ena-
bled in this mode.
Shutdown
You can shut down the heater by pressing the heating switch (3) continuously for
at least 2 seconds. The power indicator light (7) will go out immediately. The red
combustion indicator light (1) will continue to blink for about five minutes, while the
device is cooling down. You cannot restart the device until the combustion light has
stopped blinking.
When adjusting the effect from the regulation knob, the effect
adjusts smoothly.
1