90 t / 800 t
490527A
- 78 -
en
Maintenance
The glow primer does not
receive sufficient current.
(The glow primer does not
heat up to a sufficient
temperature.)
Check the power cord
connections, joints and the
main switch.
Low fuel quality.
Change the fuel.
Check the battery voltage.
Water in the fuel.
Dewater the fuel or replace it.
Water in the flue gas hose.
Check the bends and loops
of the flue gas hose for water
(water trap).
The stove smokes
when started up.
Check the battery voltage.
The battery voltage under
load must be at least
10.7 V
Water in the fuel.
Dewater the fuel or replace it.
Water in the flue gas hose.
The fuel has run out or its
level is too low for the intake
hose in the tank to reach it.
Check the bends and loops
of the flue gas hose for water
(water trap).
Add fuel.
The stove goes out
during use.
Check the condition of the
battery and the electrical
cables/connectors.
Charge the battery, if
necessary.
The burner has overheated.
Check air circulation around
the device.
High wind pressure at the
flue gas lead-through's side.
Ensure that the wind does
not blow directly in the lead-
through.
3.0.3_GB
K
00017
FAULT INDICATION WITH
BLINKING LIGHTS