background image

 

2021 

WAGENER SPARKY RU Installation & Operating Instructions 

  
Part 1: Installation Instructions for  

 WAGENER SPARKY RU (Rural Woodburner) 

(Please keep these Instructions for future Reference) 

 

The Wagener Sparky RU Freestanding Woodburner has been tested to and 
complies with AS/NZS 2918:2001- Domestic Solid Fuel Burning Appliances. 

 

Important Message to the Owner 

 
BEFORE lighting

 your first fire 

PLEASE

 read fully the Part 2 Operation & Maintenance Instructions with 

your Wagener Sparky RU. Your insurance company may require notification of the installation. Please check. 
BIA: As from 22 April 2003 Automatic Smoke Detectors/Alarms are mandatory in all new homes and when 
solid fuel heating appliances are installed. Permits will not be signed off if alarms are not fitted. 
If a Wet Back is fitted it must be connected to the water supply or damage will result. Such damage is not 
covered by Warranty. Wet backs must be installed by a Registered Plumber. 
 

Important Message to the Installer  

 

Installer’s Responsibilities 

 

The Wagener Sparky RU must be installed in accordance with these installation instructions to comply with 
AS/NZS 2918-2001-Domestic Solid Fuel burning appliances. 

 

Any variation from these installation instructions or any doubts about them must be checked against the 
requirement of the AS/NZS 2918-2001 
 
The installation must be carried out by a suitably qualified installer.  
We recommend using an accredited NZHHA Technician 
 

 

WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN 
ACCORDANCE WITH AS/NZS 2918: 2001 AND THE APPROPRIATE REQUIREMENTS OF 
THE RELEVENT BUILDING CODE OR CODES. 

 
 

THE APPLIANCE AND FLUE SYSTEM SHOULD NOT BE MODIFIED IN ANY WAY 
WITHOUT THE WRITTEN APPROVAL OF THE MANUFACTURER. 

 
 

CAUTION

: MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES 

OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN 
HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER 
SHOULD BE CONSULTED IN THE FIRST INSTANCE. 

 

CAUTION

: CRACKED AND BROKEN COMPONENTS, e.g. GLASS PANELS OR FIRE BRICKS, MAY 

RENDER THE INSTALLATION UNSAFE. 
 

PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER WHEN THE INSTALLATION IS COMPLETED 
 

Summary of Contents for Sparky RU

Page 1: ...staller s Responsibilities The Wagener Sparky RU must be installed in accordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variati...

Page 2: ...minimum size of 610mm wide and 865mm deep eg Tiles slate treadle plate etc The Ash Hearth floor protector shall have an upper surface including grouting if required of a durable non combustible mater...

Page 3: ...001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER 100 370 370 797 797 865 485 460 540 340 797 865 160 Ashlip to...

Page 4: ...E PIPE 150MM INNER CASING CEILING PLATE CERAMIC CEILING SPACER NOGGING Ash Hearth Floor Protector 100mm Flue Pipe Flue Flange Flue Shield Flue collar panel WAGENER Sparky RU 4 2 Metres from above flue...

Page 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Woodburners Flue Spigot Check that the Woodburners location allows the OUTER CASING to clear all the structu...

Page 6: ...e bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER CASING into the OUTE...

Page 7: ...BREACHING AS NZS2918 2001 6 WARNING OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE...

Page 8: ...of the firebox Stack kindling around the newspaper like an Indian Tepee and light the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or...

Page 9: ...causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect complete combustion of the fuel...

Reviews: