background image

Warranty

Sparky CAs

 firebox is 

covered by a 5 year warranty 
(Please refer to Installation & 
Operating Instructions for full 
details).

Wagener Stoves have over 
40 years experience in the 
heating industry and have been 
members of the NZ Home 
Heating Association for over 
30 years.

Other Products 

Manufactured by 

Wagener Stoves

Wagener Stoves also design and 
manufacture “Lion” Wetbacks, the 
CookTop Wagener Stove, Butler 
Multi High Performance Hot Water 
Heaters, Traditional Style Slow 
Combustion Wagener Fairburn 
Cookers, Wagener Sparky and 
Wagener Leon.

WAGENER STOVES "LION" 

LTD

5 Allen Bell Drive, Kaitaia 0410

New Zealand

Phone: 09 408 2469

www.wagenerstoves.co.nz

At Wagener Stoves we are continually 

improving our products and therefore 

specifications and designs may change 

without prior notice

2019

N E

W   Z

E A L A N D   M A D

E

Diagram C

Diagram B

3m

3m

3m

1m (min)

0.6m

or less

More than 3m

*increase flue

height as 

needed to be 

clear by 3m

Flue Installation

It is imperative that the connection between the flue and the 

flue spigot is sealed using a recommended flue sealant. If an 
offset bend is required it should be as steep as possible to 

enable ease of cleaning.  Extra flue height may be required to 

compensate for any lack of draw through the bend. 

more on the flue than on any other single component 

We recommend 4.2 metres of flue.

4

COWL

200MM

OUTER

CASING

PERLIN

FLASHING

Inner casing
200mm above 
roof line

100MM

FLUE PIPE

150MM

INNER

CASING

CEILING

PLATE

CERAMIC

CEILING

SPACER

NOGGING

Ash Hearth
Floor Protector

100mm

Flue Pipe

Flue Flange

Flue Shield

Flue collar 

panel

WAGENER

Sparky 

RU

4.2 Metres from above flue collar panel to top of flue pipe

The top of the flue system should be at least 1000mm above 

the roof or at least 600mm higher than any obstacle or ridge 
within 3 metres of the flue. The flue pipe shall extend 

not less 

than 4.6M ABOVE the top of the floor protector.

 

However a total minimum vertical height ABOVE the Wagener 

Joints between sections of the flue pipes are push fitted so that 

the upper section enters the bottom section and must be 
SEALED using a flue sealant.

 

Each section should be secured to prevent separation using 

three

 

stainless

 

steel self tapping screws or 

three monel steel

 rivets. Only flue 

systems which comply with the AS/NZS 2918-2001 should be used.
Please follow flue manufacturers instructions on page 5 and 6 

“100mm Free Standing Woodfire Flue Kit Installation” 
Instructions’. 

NB. Bird netting is available

designed 100/150/200 flue system with reduced sized flue 
shield and ceiling plate for improved performance. However a 
tested 100/200/250 system is compliant with the requirements 

of the standard but may cool the flue and affect the 

Roof line

CASING

COVER

1000mm

30mm

gap

2021

Sparky RU

The Wagener Sparky RU uses a 100mm diameter flue.

The performance of  Wagener Sparky RU depends

as it is the draw on the flue that drives the Sparky RU.

Sparky RU of 4.2 metres is recommended for adequate draft.

Note: Wagener Sparky RU has been tested with a purpose

performance of Sparky RU.

Summary of Contents for Sparky RU

Page 1: ...staller s Responsibilities The Wagener Sparky RU must be installed in accordance with these installation instructions to comply with AS NZS 2918 2001 Domestic Solid Fuel burning appliances Any variati...

Page 2: ...minimum size of 610mm wide and 865mm deep eg Tiles slate treadle plate etc The Ash Hearth floor protector shall have an upper surface including grouting if required of a durable non combustible mater...

Page 3: ...001 Please ask your retailer or contactWagener Stoves if you need further advice Installation Clearances AS NZ Standard 2918 2001 WAGENER 100 370 370 797 797 865 485 460 540 340 797 865 160 Ashlip to...

Page 4: ...E PIPE 150MM INNER CASING CEILING PLATE CERAMIC CEILING SPACER NOGGING Ash Hearth Floor Protector 100mm Flue Pipe Flue Flange Flue Shield Flue collar panel WAGENER Sparky RU 4 2 Metres from above flue...

Page 5: ...proposed position and mark a point on the ceiling that is directly above the centre of the Woodburners Flue Spigot Check that the Woodburners location allows the OUTER CASING to clear all the structu...

Page 6: ...e bottom FLUE PIPE securing the 3 Monel rivets 10 Check that the FLUE PIPE SPACING BRACKETS inside the INNER CASING are correctly positioned and then from the roof slide the INNER CASING into the OUTE...

Page 7: ...BREACHING AS NZS2918 2001 6 WARNING OPEN AIR CONTROLTO FULL AIR SUPPLY BEFORE OPENING FIRE DOOR 7 CAUTION THIS APPLIANCE SHOULD NOT BE OPERATED WITH A CRACKED GLASS 8 CAUTION THIS APPLIANCE SHOULD BE...

Page 8: ...of the firebox Stack kindling around the newspaper like an Indian Tepee and light the newspaper or firelighters if using leaving the door slightly ajar until the kindling is well alight Then add 2 or...

Page 9: ...causing damage Fire Box Bricks Fire Bricks serve two purposes Firstly to protect the steel chassis and secondly to maintain high temperatures in the fire box to effect complete combustion of the fuel...

Reviews: