118
wallaceperimetersecurity.com
Phone: 866.300.1110
TROUBLESHOOTING
Improper End Positions
Error
Description
Cause
F�000
Gate position too far
open.
‒ Too small a parameter value for upper emergency
limit switch.
‒ Value of parameter
P�233
(limit switch band) too
small.
‒ Mechanical adjustments potentially required.
F.005
Gate position too far
closed.
‒ Too small a parameter value for lower emergency
limit switch.
‒ Lower limit switch range (limit switch band) too
small.
‒ Mechanical brake defective or improperly set.
Positioning Errors in Gate Movement
Error
Description
Cause
F�020
Run time exceeded
(during opening, closing
or deadman).
Current motor run time has exceeded set maximum run
time, gate may be sticking or is blocked.
F�030
Motor Stall
Usually caused by an obstruction blocking the gate
movement or the motor brake (24VDC) not getting power,
thus not releasing, and stalling the motor. Inspect for:
‒ Mechanical wear and tear.
‒ Gate or motor blocked by obstruction.
‒ Too little speed.
‒ Absolute or incremental encoder not tightened
sufficiently in its mounting.
‒ Wrong positioning system selected
(P.205)
.
‒ Failure of relay to brake or failure of brake.
F�031
Detected rotational
direction deviates from
expected.
‒ Commonly caused by mechanical wear and tear.
‒ When using incremental encoders: Channel A and
B reversed.
‒ Motor rotation direction reversed compared with
calibration setting.
‒ Too much “pancaking” when starting, brake
releases too soon, or too little torque; adjust
boost as necessary.
F�060
Breakaway Failure
This function is NOT USED. Ensure Parameter
P�870
is set
to
zero
.
Summary of Contents for SPEEDGATE
Page 48: ...48 wallaceperimetersecurity com Phone 866 300 1110 SPEEDGATE INSTALLATION...
Page 52: ...52 wallaceperimetersecurity com Phone 866 300 1110 SPEEDGATE INSTALLATION...
Page 59: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 1...
Page 60: ......
Page 61: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 2...
Page 62: ......
Page 63: ...PDXT PDXT C and PDTT Electrical Point to Point Diagrams 3...
Page 64: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 141: ......