7. Place the appropriate feeler gauge, with reference to
Table 7-2
, between the tip and the
casing 4 in (10 cm) from one end of the blade tip, place a second feeler gauge of the
same size 4 in (10 cm) between the tip and the casing at the other end of the tip.
Figure 7-32: Feeler gauge placement
8. Gently lever the tip upwards until it contacts both feeler gauges.