The Control Panel Sections
36
Kyra Manual
Oscillator Group 1 & Hypersaw Pages
You can navigate to the Oscillator Group 1 Control page
using the Oscillator Group 1
Select
button or by changing a
control in the group with Follow Mode engaged. All para-
meters shown have physical controls.
Oscillator 1 Coarse Tune
r
Please see the description of the
Oscillator Group 1
Tune
control.
Oscillator 1 Wavetable 2 FM
This controls sets the amount of FM (frequency modulati-
on) of the three core Oscillator Group 1 source (sawtooth,
pulse and wavetable) from Oscillator Group 2's wavetable.
r
There’s more information about FM on Kyra in the
Sound Programming section of this manual.
LFO1 to Pitch
r
You can adjust amount of
LFO1 to Pitch
using the
Saw Level
control with Shift Mode engaged.
This control sets the amount of hard-wired modulation
from LFO1 to Pitch. It is only effective in Wave Mode. Plea-
se use the LFO1 to Pitch control in Oscillator Group 1 to
apply modulation to the hypersaw.
Remember that the Oscillator Groups modulations are
independent so if you apply a modulation, such as LFO1 to
Pitch, to Oscillator Group 1, it does not affect Oscillator
Group 2. If you want both groups to be modulated in the
same way (e.g. the same pitch modulation using LFO1 to
Pitch) you must set the modulation in both Oscillator
Groups. This gives you maximum flexibility as you can
modulate the two groups by different amounts to get all
sorts of useful effects.
g
Applying stereo LFOs and different modulating
shapes to Oscillator Pitch can produce some ama-
zing effects.