765-1202/0100-0000
Functions
Product manual | Version: 1.0.0
31
16DIO FLD EC DC 24V 2.0A
Note
Read the online help!
You can find Product-specific information on the WAGO App I/O Field in the online help
for the app.
An iOS version of the WAGO I/O Field app is available for free in the Apple App Store,
and an Android version in the Google Play Store.
5.6 Communication Interfaces
The module has the following interfaces and supports the following protocols:
• ETHERNET Interfaces
– EtherCAT
®
– HTTP for the WAGO Webserver I/O Field
– TCP for the OPC UA server
– UDP for the WAGO IO-Link Configurator
• Bluetooth
®
for the WAGO I/O Field app
5.6.1 EtherCAT
The module exchanges the process data with the controller via EtherCAT
®
. The process
data communication requires the controller and module to be configured and parameter-
ized.
5.6.2 OPC UA Server
The module has an integrated OPC UA server.
Function Overview
• Read module identification
• Read configuration
• Read measured values: current, voltage, temperature
• Events: overcurrent, overload and overtemperature
• Read status information
• Read process data
• Read statistics: minimum/maximum current per pin, minimum/maximum voltage per
pin, minimum/maximum temperature
• User access: anonymous (only read access) or username/password (read and write
access)