![WAGNER AquaCoat 5010 GA 5000EAW Operating Manual Download Page 93](http://html1.mh-extra.com/html/wagner/aquacoat-5010-ga-5000eaw/aquacoat-5010-ga-5000eaw_operating-manual_3230262093.webp)
93
VERSION 03/2018
ORDER NUMBER DOC 2369735
1
B_06042
X = 130 ±0.1 mm
X = 5.12 ±0.004 inch
2
6
2Nm; 1.48 lbft
SW7
SW7
2
2
2
2
3
4
B_05786
Coat the hollow section with a brush.
Note: avoid the pin and hexagon.
(sparingly)
Valve rod unit:
Set length adjusting measure X with collet
chuck (6) and lock with a hexagon nut (2).
2
2
3
4
2
SW5
10
5
0.5 Nm
0.37 lb ft
SW7
0.4 - 0.5 Nm
0.3 - 0.37 lb ft
B_05800
1
0.8 Nm + 0.1 Nm;
0.6 + 0.07 lbft
Wear gloves!
The outside thread of the packing (3) must be free of lacquer.
Grease, push and screw valve rod unit (4) and packing (3) together.
Grease clamping screw (1) and mount using assembly tool (5).
Only as required
(if the rod seal was
removed): Press in rod seal (10).
In the process, press only on the lowest
area of the rod seal.