![WAGNER AquaCoat 5010 GA 5000EAW Operating Manual Download Page 75](http://html1.mh-extra.com/html/wagner/aquacoat-5010-ga-5000eaw/aquacoat-5010-ga-5000eaw_operating-manual_3230262075.webp)
75
VERSION 03/2018
ORDER NUMBER DOC 2369735
Pin no. Designation
Description
3 out
Fault output
If there is a fault, +24 V DC is issued at pin 3 in reference to pin 8 (ground).
Maximum current 0.5 A
4 in *
DC kV in
Set value specification for high voltage. *
Analog d.c. voltage input at pin 4 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
8.0 V is a maximum specification and corresponds to 80 kV
6 out
DC kV out
Output of current actual voltage.
Analog d.c. voltage output at pin 6 in reference to pin 8 (ground).
0.1 V corresponds to 1 kV
8.0 V is a maximum specification and corresponds to 80 kV
7 out
DC µA out
Output of current actual spraying current.
Analog d.c. voltage output at pin 7 in reference to pin 8 (ground).
0.1 V corresponds to 1 μA
10.0 V is a maximum specification and corresponds to 100 μA
* If the external voltage set value specification function is to be used, parameter C12 must be set to "on" at the
VM 5020WA control unit (see Chapter
Analog output
The analog outputs are not power outputs, but merely
signal outputs
.