DEVICE CONFIGURATION
7.5.1 OVERVIEW OF PARAMETERS
Parameter
Value
Description
C12 External set value
specification
off
(factory setting)
The target values for high voltage in kV
and current limitation in µA are adjusted at
the front control panel of the control unit.
on
- The target value for high-voltage in kV
is defined by an analog voltage input of
the interface. Application example: Set
value specification by a superordinate
controller (PLC).
- The spray current limitation is fixed at
100 μA.
- Set values can no longer be adjusted at
the front control panel. All recipe functions
(save, call up recipe, etc.) are locked.
C13 Lock
off
Lock is deactivated.
(factory setting)
on
Operating inhibit is activated.
- You can select recipes and control
functions.
- The set values (kV and µA) cannot be
adjusted.
pro
Lock pro (program).
- You can select recipes and control
functions.
- The target values (kV and µA) can be
adjusted but cannot be saved in the
recipes.
C19 Reset recipes
no
No reaction
(factory setting)
res
All programs are set to delivery condition,
if "res" is saved with the "Service" button.
C20 Reset
configuration
no
No reaction
(factory setting)
res
All configuration parameters are set to
delivery condition (factory setting), if "res"
is saved with the "Service" button.