86
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
9.1.4 CLEANING THE SYSTEM
The system should be cleaned for maintenance purposes. Ensure that no remaining
product dries on and sticks to the device.
A cleaned system allows an easy localization of any leakage and quick repair.
Procedure:
1. Relieve the pressure according to Chapter
2. Service guns and pumps according to their operating manuals.
3. Clean and check the suction systems and suction filter.
4. Product filter: check and clean filter insert and filter body.
5. Put the whole system back together.
6. Clean the outside of the system.
9.1.5 DECOMMISSIONING
1. Clean the system according to Chapter
2. Fill the entire system with flushing agent. As laid down in Chapter
, but with
flushing agent.
WARNING
Gas mixtures can explode if there is an incompletely filled pump!
Danger to life from flying parts.
Ensure that the device is always completely filled with flushing agent or working medium.
Do not spray the device empty after cleaning.
9.1.6 LONG-TERM STORAGE
If storing the system for a prolonged period of time, thorough cleaning and corrosion
protection are necessary. For the last rinse, replace the water or solvent in the product
pumps with a suitable preservative. Fill separating agent cup with separating agent.
Store pump vertically.
Procedure:
1. Clean the system according to Chapter
2. Fill the entire system with flushing agent. As laid down in Chapter
, but with
flushing agent.
3. Fill the entire system with preservative according to Chapter
and the lacquer
supplier's instructions.
4. If the discharge duct is to be removed, seal product outlet with plug.
5. If the suction system is to be removed, seal product inlet with plug.
6. Storage according to Chapter
.