66
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
7.13 SETTINGS
7.13.1 PASSWORD LEVEL 2 SETTINGS
Level 2
Menu
There are 24 pages of settings. Depending on configuration, pages may be jumped.
The page numbers with a gray background always appear, the others are optional. (Detailed
descriptions of these pages can be found in the 2K COMFORT Software Documentation.)
1 Number of
paint recipes
and number of
flushing recipes
.
QB,
QC, QD Control
See the software documentation, "Diagnosis" chapter.
Gun Delay
Delay time for alarms A106 to A113 (set "Minimum flow" and "Maximum
flow" Chapter
, level 3, page 4)
2
Post-alarm for pot life
Once the pot life + post-alarm times have passed, the
system stops (alarms A132–A144). The alarm is repeated until the system is flushed.
If "Automatic flushing at pot life alarm" is activated, and the guns are in the gun flush
box, flushing is started automatically.
Alarm delay Flow monitoring
Delay time for alarms A121 and A122. (Activate
"Flow monitoring", Chapter
, level 3, page 2. Enter the limits in the paint
recipe see Chapter
Atomizing air at alarm stop
So that coating can be completed without dripping.
Atomizing air at end of flushing
To blow the air cap free.
VOC measuring unit
Percent or gram per Liter.
Password
for password level 1.
3 Hose dimensions from product valves A and B to mixer.
4 For 3K system: hose dimensions from product valve C to mixer.
5 For 4K system: hose dimensions from product valves C/D to mixer.
6 Hose dimensions from mixer to splitter valve.
7+8 − Page 7: Hose dimensions from mixer to gun 1.
− Page 8: Hose dimensions from splitter valve to gun 1.
Gun content of gun 1
Gun 1:
Filling via the dump valve
Quantity (as a percentage), which should be
discharged via the dump valve. (The remainder passes via the gun.)
Gun 1:
Flush atomizing air % hose content
When flushing: What percentage of the
hose content from the mixer to the gun, can still be used for coating. The atomizing
air (and electrostatics) for gun remains activated for this period when flushing.
See also "Flushing pause" (level 2, page 16).
Gun 1:
dump valve flushing time
after filling. (Only with flushable dump valve.)
9 Hose dimensions from gun 1 to the dump valve. (Only with "Dump valve as return flow".)