67
OPERATING MANUAL
VERSION 05/2017
ORDER NUMBER DOC 2357061
10+11 Like pages 8 + 9, but for gun 2.
12+13 Like pages 8 + 9, but for gun 3.
14+15 Like pages 8 + 9, but for gun 4.
16 The
flushing pause
indicates that with "Atom.air on flush % of hose volume" the
remainder must be sprayed into the waste tank. The atomizing air remains on during
the flushing pause.
Pot life alarm
Flushing
"On" = Flushing is mandatory after a pot life alarm.
Additional spraying is also possible with "Off".
Mixing alarm
Flushing
"On" = Flushing is mandatory after a mixing error alarm
(A100–A118, A128–A131, A145–A148). Additional spraying is also possible with "Off".
Mixing alarm
Filling
"On" = Filling is mandatory after a mixing error alarm
(A100–A118, A128–A131, A145–A148). Additional spraying is also possible with "Off".
17
Filling greater than hose content
What percentage of the total hose content is
also to be filled between product valve and gun to ensure that there is no flushing
agent left in the hose.
Flow monitoring during filling
"On" = The flow is limited when filling to optimize
the dosing quality. Set limits with "Max. filling flow" or "Min. filling flow". If necessary,
the A valve cycles (see figure).
Reset pot life
Pot life is reset manually.
Flow monitoring during filling
B_06130
a
b
c
"A" valve open
"A" valve closed
Time
(a) During filling, the flow is regulated by a longer or shorter opening of the A valve.
(b) "Filling time period" (in seconds)
(c) "Maximum time period open" (in percent of (b))