background image

WAFER GSM-HOUSE INTERCOM UNIT 

http://www.waferstar.com 

#PWD123456#SHL=ALL?

   

(Instruction Only for 

PC)

 

Acknowledge 

:  

SHL01 IS XXX 

SHL03 IS XXX 

QHL08 IS XXX 

…… 

 

#QUERY Query the phone number in the WHL list. 

(

PC$PHONE)

 

Query the phone number in the position of the WHL list,Special phone list or Alarm phone list 

#PWD123456#QUERY=143535353 

  (

PC$PHONE)

 

Acknowledge

:  QUERY RESULT: 143535353 AT WHL004 

 

#ACM Safety control or free control mode setting.   

(

PC$PHONE)

 

#PWD123456#ACM=ON 

Acknowledge

:ACM SET TO ON

 

#PWD123456#ACM=OFF 

Acknowledge

:ACM SET TO OFF

 

ACM=OFF, Then any number can free control the device through the phone calling 
ACM=ON, Then only the authorized number can control the device through the phone calling 

 

#GOT Relay working output delay time.   

(

PC$PHONE)(Only for NO.1 Relay)

 

When setup the GOT Timer,first you also need to setup the timer 

multiplier at millisecond or second 

or minutes. 

#PWD123456#GOT5000:MILLISECOND 

Acknowledge

:DELAY TIME SET TO 5000 MS

 

#PWD123456#GOT500:SECOND 

Acknowledge

:DELAY TIME SET TO 0500 S

 

#PWD123456#GOT500:MINUTE 

Acknowledge

:DELAY TIME SET TO 0500 M

 

This command is useful in case you need to keep the Relay output working longer. The standard 
time is 5 seconds (5000 ms). You can change it with the GOT command. 
With the above command the delay time has been set to 5000 ms (5 seconds). 
You can check what the current relay output delay time is with the command 

#PWD123456#GOT?  

(

PC$PHONE) (Only for NO.1 Relay) 

Acknowledge

DELAY TIME IS 05000 MS 

 

#ALARM Alarm setup 

In GSM-HOUSE V2015,that Alarm01 is very important position,not only act as a alarm number,but also 

working as the REPORT phone number, that means if you enable the REPORT function,then every report 

event happen,then would send the REPORT SMS to this number 

(1)You can setup the alarm phone number when have the alarm information input 

#PWD123456#ALARM01=13818120592  

(

PC$PHONE)

 

Where 01 is the position in the list

 

Summary of Contents for GSM-HOUSE

Page 1: ...WAFER GSM HOUSE INTERCOM UNIT http www waferstar com GSM HOUSE MANUAL New version published from 2016 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...hen not at home The unit does not need any special installation or complicated wiring it fixes to a wall or post and then only needs power supply and an active SIM card For the GSM KEY function It has...

Page 3: ...all the GSM HOUSE in a place where there is GSM signal coming from the operator you want to use Check it with a phone before proceeding with the installation If you need to install the device in a pla...

Page 4: ...GRAMMING You can program the GSM HOUSE with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it we als...

Page 5: ...aximum 200 numbers can be configured 9 Controlling by SMS command or customized command Please refer to the following SMS command to control the relay1 and relay2 and also can use the customized SMS c...

Page 6: ...reset it and this has a cost The CAP command must be issued 2 times to be sure you don t digit a wrong one OF course it must be preceded by the old password For example to change the password 123456...

Page 7: ...3 IS XXX WHL08 IS XXX SHL PHL QHL Special List Set from what time to what time you want these numbers operate PWD123456 SHL001 13564121668 1357 8 32 23 59 Acknowledge SHL001 SETUP TO 61143815 1357 8 3...

Page 8: ...llisecond or second or minutes PWD123456 GOT5000 MILLISECOND Acknowledge DELAY TIME SET TO 5000 MS PWD123456 GOT500 SECOND Acknowledge DELAY TIME SET TO 0500 S PWD123456 GOT500 MINUTE Acknowledge DELA...

Page 9: ...m input then will phone the number in the alarm phone list until you reject the phone call or that will continue to phone the number again after the minutes setted If at SMS mode When receive the alar...

Page 10: ...RM2 HIGH BCPW 69 CSQ 20 RELAY1 OFF RELAY2 OFF BCPW is the remaining power OUT Control the Relay Output on or off PC PHONE PWD123456 OUT1 ON or OFF Acknowledge OUT1 ON OK or OUT1 OFF OK PWD123456 OUT2...

Page 11: ...lay PWD123456 CLOSE2 TEXT GATE2 CLOSE Reply CLOSE TEXT2 IS GATE2 CLOSE Then you can use the simple SMS GATE2 CLOSE to switch off the output2 relay PWD123456 RLY TEXT2 GATE2 DIAN Reply RLY2 TEXT IS GAT...

Page 12: ...ton for release the out1 and out2 PWD123456 RELEASE1 1 Reply RELEASE1 1 OKAY PWD123456 RELEASE2 2 Reply RELEASE2 2 OKAY You only need to input one number but every time you need press more than twice...

Page 13: ...WEIFU GSM Modules For further information and queries kindly contact Email wafer waferstar com Web www waferstar com Tel 0086 21 51870528 Also accessible via our online Service Skype wafer service If...

Reviews: