Service tasks
✓
The device evacuates the service hoses.
8. Unscrew the service couplings from the service hoses (
7
) and (
8
).
9. Press
ENTER
to confirm.
✓
The device equalizes with the ambient pressure.
10. Screw the service couplings hand-tight onto the service hoses (
7
)
and (
8
), taking care not to mix up the red and blue markings on the
couplings and hoses.
11. Use the keypad (
2
) to enter the current local atmospheric pressure
and press
ENTER
to confirm.
I
12. When calibration has been completed, press
ENTER
to exit the
menu.
13. Press
STOP
twice to access the standby menu.
14. To evacuate the service hoses, perform a short vacuum phase (see
chapter “Free selection” on page 87).
HP/LP connectors
removed ?
NOTE
You can look up the current atmospheric pressure for your region on the
Internet, for example at http://www.meteo24.de/wetter/ under “air pres-
sure”.
Summary of Contents for AirConServiceCenter ASC5100G
Page 2: ......
Page 220: ...RU ASC5100G 220 1 2 A I ENTER 1 2 3 1 2 3 1 229 230 2 A E...
Page 224: ...RU ASC5100G 224 2 3 405 C A AirConServiceCenters I R 1234yf...
Page 225: ...RU 225 ASC5100G 2 4 TRG 402 AirConServiceCenter...
Page 226: ...RU ASC5100G 226 2 5 AirConServiceCenter 230 50 2 6...
Page 230: ...RU AirConServiceCenter ASC5100G 230 6 2 10 11 12 13 11 10 13 12...
Page 236: ...RU ASC5100G 236 7 7 I 1 10 11 R 1234yf 11 10...
Page 243: ...RU 243 ASC5100G I 8 2 2 1 STOP ENTER USER CODE WRONG CODE John Citizen...
Page 257: ...RU 257 ASC5100G 10 D 11 E 12 15 13 14 D E...
Page 261: ...RU 261 ASC5100G 9 5 1 10 2 D E AirConServiceCenter D E D E...
Page 267: ...RU 267 ASC5100G 10 1 2 7 8 AirConServiceCenter 3 AirConServiceCenter AirConServiceCenter...
Page 268: ...RU ASC5100G 268 11 11 1 I 11 2 11 3 AirConServiceCenter M...