wc_tx003206gb.fm
33
HDR 155
Operation
4.11
Starting the Machine
Requirements
Machine properly positioned
Power connected
Pre-starting checks completed
Procedure
To start the machine, follow the procedure below.
1. Select an operation mode.
a. Continuous heat mode
(I)
b. thermostat mode
(II)
Operational
sequence
The following sequence of events will occur.
1. The burner blower will start.
2. The burner will start firing.
In applications in which the remote thermostat is not being used
(I)
, the
burner will fire continuously.
In applications in which the remote thermostat is being used
(II)
, the burner
will fire until the air temperature of the application area reaches the target
temperature set by the remote thermostat. At that time, the burner will shut
off. When the air temperature of the application area falls below the target
temperature set by the remote thermostat, the burner will refire. The process
continues as long as there is fuel for the burner.
WARNING
Burn hazard. The external surface of the machine and fuel filter may be hot.
f
Wear safety gloves when handling the machine components.
wc_gr010009
RESET
ON
ON
ON
ON
ON
ON