background image

NOTE: It is possible to connect a second RL-IR305 Distribution  

      Module if multiple of the same devices that require  

       

      controlling are housed in different locations.  Outputs           
      DISCRETE  A / B / COMMON are the same on both 

 

      RL-IR305’s.

by

1.  IR Distribution Hub allows connection of 1 Distribution 

Module (RL-IR305) and up to 7 Receiver Modules 

 

(RL-IR505) to be connected to a single point, eliminating 
unnecessary issues.

2.  Modules can be connected to the system in a star wired 

configuration by:

 

(a) running UTP cable from RJ45 socket on Distribution 
and/or Receiver Module (RL-IR305/505) to RJ45 socket on 
front of IR Distribution Hub.

 

(b) running UTP cable from RJ45 socket on Distribution 
and/or Receiver Module to punchdown terminations on rear 
of IR Distribution Hub.

 

NOTE: A combination of Option 1 and 2 is also possible

3.  POWER LED indicator on IR Distribution Hub remains 

illuminated while RL-IR305 is powered. 

4.  IR LED indicator on IR Distribution Hub illuminates briefly

 

upon receipt of IR commands.

INSTALLATION MANUAL

IR Distribution Hub (RL-IR170)

WARRANTY

Vcomm Pty Ltd states that the warrant that the customer can rely on is that 

provided by the manufacturer.  In the event of any warranty claim please 

contact us and we will forward it to the manufacturer. The manufacturer will 

then determine the extent of their liability.  This expressly negates, to the 

extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd.

ABN: 99 091 281 524

Vcomm Pty Ltd

www.resi-linx.com

Patented

RL-IR170

linx-IR Repeater System

resi-linx

   

 Discrete IR System

®

¸

linx-IR Distribution Hub

Connections

8 x 8 way IDC terminations

8 x RJ45 sockets

Cable Requirement

UTP

Max cable length per system

Up to 60 metres

Max Targets per system

Up to 7 targets

Power Requirement

Powered remotely by 

Distribution Module

  Troubleshooting

 

NOTE: Some brands of TV/Monitors can reduce the range 
of the IR Receiver head, which is outside the scope of the 
warranty.

UTP cable

RL-IR305

Distribution Module

RL-IR170

Distribution Hub

(rear)

Option 2

B

A

A  RJ45 sockets 
B  IDC Terminations

RL-IR170

Distribution Hub

(front)

RL-IR505

Receiver Module

Option 1

UTP cable

RL-IR305

Distribution Module

RL-IR505

Receiver Module

A

A

A

A

B

A

RL-IR505

Receiver Module

Reviews: