![Wacker Neuson HDR155 Operator'S Manual Download Page 34](http://html1.mh-extra.com/html/wacker-neuson/hdr155/hdr155_operators-manual_3131262034.webp)
wc_tx003206gb.fm
34
Operation
HDR 155
4.12
Stopping
Procedure
Follow the procedure below to stop the machine.
1. Turn the operation mode switch to the OFF (0) position
(c)
.
Shut-down
sequence
The following sequence of events will occur after turning the machine off.
1. The burner will shut down.
2. The blower will stop when the machine is sufficiently cool.
4.13
Operating Status Indicators
Overview
Two lamps
(a, g)
on the control panel display the operating status of the machine.
Burner fault
lamp
The burner fault lamp / reset button
(a)
is illuminated while the machine is
operating.
If the burner fault lamp / reset button is green, the machine is operating
normally.
If the burner fault lamp / reset button is red, the machine is in a burner lock-out
state. The burner lock-out must be cleared before machine operation can
resume.
To clear a burner lock-out, press and hold the burner fault lamp / reset button until
the lamp goes out.
Power
indicator
The power indicator
(g)
illuminates if the supply power is present.
See
Basic Troubleshooting
or contact Wacker Neuson for additional help if
necessary.
WARNING
Electric shock hazard. Electric power is still active at the blower even when the
machine is turned OFF.
f
Remove all electric power to the machine before servicing the machine.
c
ON
ON
RESET
ON
ON
g
a
wc_gr010010