GP Repair
Operation
wc_tx000545gb.fm
25
3.
Operation
3.1
Information Regarding Operation
The information regarding the operation of the machine included in this
manual is condensed. Refer to the Operator’s Manual for complete
operating instructions. Always read, understand, and follow the
procedures in the Operator’s Manual when operating the machine.
3.2
Determining Power Requirements
This generator is designed to operate single-phase, 60 Hz appliances
running at 120 VAC or 240 VAC. Check the nameplate or label
provided on tools and appliances to make sure their power
requirements match the power output of the generator.
Some appliances and tools require a surge of current when starting.
This means that the amount of power needed to initially start the
equipment is larger than the power required to keep it running. The
generator must be capable of supplying this “surge” current. Other
types of appliances require more power than is actually stated on their
nameplate.
The information in “Approximate Starting Power Requirements” is
offered only as a general guideline to help you in determining power
requirements for different types of equipment. Check with your nearest
Wacker Dealer, or contact the manufacturer or dealer of the tool or
appliance, with questions regarding its power requirements.
CAUTION:
If a tool or appliance does not reach full speed within a few
seconds when switched on, turn it off immediately to avoid damage.
Approximate Starting Power Requirements:
•
Incandescent lights and appliances such as irons and hot plates, which
use a resistive-type heating element, require the same wattage to start
and run as is stated on their nameplates.
•
Fluorescent and mercury lamps require 1.2–2 times their stated
wattage to start.
•
Electrical motors and many types of electrical tools often require a
large starting current. The amount of starting current depends on the
type of motor and its use.
•
Most electrical tools require 1.2–3 times their stated wattage for
starting.
•
Loads such as submersible pumps and air compressors require a very
large force to start. They need as much as 3–5 times the wattage
stated on the nameplate in order to start.
Summary of Contents for GP 3800A
Page 2: ......
Page 13: ...GP Repair Safety Information wc_si000169gb fm 9 1 4 Label Locations GND 88897...
Page 25: ...GP Repair Technical Data wc_td000169gb fm 21 Notes...
Page 50: ...Maintenance GP Repair wc_tx000546gb fm 46 4 11 Electrical Schematic GP 2500A...
Page 52: ...Maintenance GP Repair wc_tx000546gb fm 48 4 13 Electrical Schematic GP 3800A 0620010 rev 104...
Page 54: ...Maintenance GP Repair wc_tx000546gb fm 50 4 15 Electrical Schematic GP 3800A 0620010 rev 103...
Page 60: ...Maintenance GP Repair wc_tx000546gb fm 56 4 21 Electrical Schematic GP GPS 5600A 6600A rev 104...
Page 62: ...Maintenance GP Repair wc_tx000546gb fm 58 4 23 Electrical Schematic GP GPS 5600A 6600A rev 103...
Page 68: ...Maintenance GP Repair wc_tx000546gb fm 64 4 29 Engine Schematic all GP GPS 3800A 5600A 6600A...
Page 70: ...Maintenance GP Repair wc_tx000546gb fm 66 Notes...
Page 77: ...GP Repair Troubleshooting wc_tx000548gb fm 73 wc_gr003415 z y...
Page 87: ...GP Repair Troubleshooting wc_tx000548gb fm 83 Notes...
Page 95: ...GP Repair Troubleshooting wc_tx000548gb fm 91 wc_gr003148 b c d a...
Page 112: ...Troubleshooting GP Repair wc_tx000548gb fm 108 Notes...
Page 115: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 111 wc_gr003136 c e f f h f g a b d...
Page 119: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 115 wc_gr003138 a d e c b f g i h...
Page 121: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 117 wc_gr003139 d d c c e f a b...
Page 123: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 119 wc_gr003141 c a b d e f...
Page 124: ...Disassembly Assembly Procedures GP Repair wc_tx000549gb fm 120...
Page 129: ......