GP Repair
Operation
wc_tx000545gb.fm
27
3.3
Outdoor Installation
Place the generator in an area where it will not be exposed to rain,
snow, or direct sunlight. Make sure it is positioned on firm, level
ground, so it will not slide or shift. Position the engine exhaust away
from areas where people may be present.
If operating the generator inside a tunnel or deep trench, make sure
there is adequate ventilation. Precautions similar to those required
when operating indoors may be necessary.
The surrounding area must be free from water and moisture. All
components must be protected from excessive moisture.
3.4
Indoor Installation
If the generator must be installed indoors, adequate ventilation or
exhaust hoses must be provided. When venting exhaust fumes, make
sure the exhaust piping is large enough to prevent excessive back
pressure to the engine. Back pressure reduces engine efficiency and
may cause the engine to overheat.
Exhaust gas from the engine contains poisonous carbon monoxide
gas; exposure to carbon monoxide can cause loss of consciousness
and may lead to death. Never run the generator indoors or in an
enclosed area unless adequate ventilation, through such items as
exhaust hoses or fans, is provided.
When installed indoors, steps to prevent fire and explosion such as
providing a good, earthen ground, removing all flammable materials
near the generator, and using only electrical cables in good condition,
must be observed. See
Operating Safety.
3.5
Recommended Battery (GPS only)
This generator is shipped without a battery. The recommended battery
to be used is:
Battery Type
50-N18L-A
Voltage
12 V
Capacity
20 A/h
L x W x H
206 x 90 x 164 mm
(8-1/8 x 3-9/16 x 6-7/16 in.)
DANGER
Summary of Contents for GP 3800A
Page 2: ......
Page 13: ...GP Repair Safety Information wc_si000169gb fm 9 1 4 Label Locations GND 88897...
Page 25: ...GP Repair Technical Data wc_td000169gb fm 21 Notes...
Page 50: ...Maintenance GP Repair wc_tx000546gb fm 46 4 11 Electrical Schematic GP 2500A...
Page 52: ...Maintenance GP Repair wc_tx000546gb fm 48 4 13 Electrical Schematic GP 3800A 0620010 rev 104...
Page 54: ...Maintenance GP Repair wc_tx000546gb fm 50 4 15 Electrical Schematic GP 3800A 0620010 rev 103...
Page 60: ...Maintenance GP Repair wc_tx000546gb fm 56 4 21 Electrical Schematic GP GPS 5600A 6600A rev 104...
Page 62: ...Maintenance GP Repair wc_tx000546gb fm 58 4 23 Electrical Schematic GP GPS 5600A 6600A rev 103...
Page 68: ...Maintenance GP Repair wc_tx000546gb fm 64 4 29 Engine Schematic all GP GPS 3800A 5600A 6600A...
Page 70: ...Maintenance GP Repair wc_tx000546gb fm 66 Notes...
Page 77: ...GP Repair Troubleshooting wc_tx000548gb fm 73 wc_gr003415 z y...
Page 87: ...GP Repair Troubleshooting wc_tx000548gb fm 83 Notes...
Page 95: ...GP Repair Troubleshooting wc_tx000548gb fm 91 wc_gr003148 b c d a...
Page 112: ...Troubleshooting GP Repair wc_tx000548gb fm 108 Notes...
Page 115: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 111 wc_gr003136 c e f f h f g a b d...
Page 119: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 115 wc_gr003138 a d e c b f g i h...
Page 121: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 117 wc_gr003139 d d c c e f a b...
Page 123: ...GP Repair Disassembly Assembly Procedures wc_tx000549gb fm 119 wc_gr003141 c a b d e f...
Page 124: ...Disassembly Assembly Procedures GP Repair wc_tx000549gb fm 120...
Page 129: ......