8 Use and operation
40
100_0202_op_0009.fm
8.3.2
Cold starting the machine (manual start)
Note:
The engine should rotate freely at temperatures below -5 °C.
1. Bring decompression lever to neutral position.
2. Crank the engine with the crank handle anticlockwise until it can rotate no-
ticeably more freely (10 - 20 crank turns).
3. Press the hand lever of the mechanical oil pressure monitoring for 15 sec-
onds.
Note:
In the area of the cover of the metering device, remove dirt and take off
the lid.
4. In the metering device add engine oil up to the upper edge.
5. Replace cover and press it in firmly.
Note:
Two fillings in succession are necessary.
6. Pull up decompression lever to the hilt.
7. Then start the engine immediately, see chapter
Starting the machine (manual
start).
Pos.
Designation
Pos.
Designation
1
Decompression lever
3
Metering device
2
Hand lever oil pressure monitor-
ing
1
3
2