9 Maintenance
52
100_0202_mt_0008.fm
6. Fill new oil (for exciter oil type and quantity see chapter
Technical Data)
in the
filler boring, use appropriate and clean filling vessel.
7. Place the machine horizontally on a level surface.
8. Screw in the screw plug with sealing ring in the filler boring.
Tightening torque
100 Nm.
Check starter battery fluid level
1. Remove battery cover.
Note:
Check for damage to the coiled helix cable.
2. Unscrew screw caps from all cells.
3. Check whether the fluid level is in all cells is above the mark.
4. When the fluid level falls below the mark, add distilled water.
5. Screw back screw caps on all cells.
WARNING
Risk of injury from corrosive acid.
Wear protective glasses and chemical resistant protective gloves.
Pos.
Designation
Pos.
Designation
1
Battery cover
3
Fluid level marking
2
Sealing caps
4
Coiled helix cable
2
3
1
4