9 Maintenance
54
100_0202_mt_0008.fm
5. Place the new starter battery and insert degassing tube.
Note:
First connect positive terminal, then the negative terminal.
6. Connect starter battery.
Note:
Before installing the battery cover, ensure that the positive terminal cover
is attached. Make sure that the degassing tube is free of kinks.
When attaching the battery, pay attention to the coiled helix cable.
7. Replace battery cover.
Pos.
Designation
Pos.
Designation
1
Positive terminal cover
2
Degassing hose
3
Coiled helix cable
3
1
2