The power supply installation must be equipped with an efficient protective installation and must meet the
requirements of the safety regulations.
Place (screw) the diamond core bit on the drilling rig holder (spindle) and tighten with open-end wrenches.
In the event of a break in work or after its completion, disconnect the machine from the mains by removing
the plug from the power socket.
Before connecting the machine, make sure that the supply voltage corresponds to the value stated on the
rating plate. The power supply installation of the machine should be made with a copper wire with a
minimum cross-section of at least 2.5 mm and should be routed through a 16A fuse.
In the event of a power failure and the machine stops, it is mandatory to release the on/off button and
remove the plug from the socket. After determining the cause of the power outage and resolving the
problem, you can continue working. Do not leave the machine connected to the mains unattended.
Make sure both the core bit and the machine spindle are clean. Any debris may cause excessive runout of
the mounted core bit. Excessive run-out can cause premature core bit failure and/or a safety hazard.
Check that the moving parts are undamaged, that there is visible damage to the machine, or that the power
cord is 100 percent functional.
Lay the electric cable so that it is not exposed to damage during operation. If you need to use an extension
cord, choose its length so that the excess does not interfere with your work. The extension cord should
also be equipped with a protective conductor. Do not disconnect the plug by pulling on the power cord.
The drilling rig has two rotational speeds of 0 - 1080/2160 rpm.
NOTE: Make sure spindle and core drill threads match. Attempting to install mismatched
components will damage the spindle and drill bit.
The device is equipped with a residual current device mounted on the power cord, at the plug. It has two
buttons and a signal lamp. If the indicator light is red, the device is ready for operation. After a power failure
or a short-circuit in the installation, the fuse will operate, cutting off the power supply - the signal lamp will
stop lighting. To prepare the machine for work again, press the "RESET" button. If the indicator light is still
off, there is no power to the mains or there is a short circuit in the installation. The "TEST" button is used to
disconnect the voltage.
Do not use a power tool with a defective on/off switch. A power tool that cannot be switched on or off is
dangerous and must be repaired.
7. DRILL MOUNTING:
8. MAINS:
9. TURNING ON THE MACHINE:
6. PREPARATION FOR WORK: