TEMPERATURE PROBE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
1.
Remove the right-side panel as outlined under
Covers and Panels.
2.
Disconnect probe leads from the solid state
temperature controller on the SG4D/SG6D or the
computer controller on the SG4C/SG6C.
3.
Remove the racks and right rack support.
4.
Remove the upper and lower door seals.
Fig. 10
5.
Loosen the three screws securing the right side
air scoop to the rear heat exchanger. Rotate the
air scoop off of the heat exchanger tube into the
oven cavity.
6.
Remove the screws that secure the perforated
side panel and lift out.
Fig. 11
7.
Remove the probe from the bracket(s).
Fig. 12
SG4C/SG6C Temperature Probe Shown
8.
Push the probe through the oven wall and into the
control panel area.
9.
Reverse the procedure to install the new probe.
10. Calibration:
A.
SG4D/SG6D: Adjust the temperature
controller as outlined under Solid State
Control Calibration.
B.
SG4C/SG6C: Adjust the computer
controller as outlined under Computer
Controller and/or Computer Controller
Calibration in Service Procedures and
Adjustments.
GAS BURNERS
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the oven.
1.
Remove the lower front cover as outlined under
Covers and Panels.
2.
There are two burners located on the bottom left
and right side of the oven. Disconnect the ignition
cable and the flame sense lead from each burner.
SG4 & SG6 Series Full Size Gas Convection Ovens - REMOVAL AND REPLACEMENT OF PARTS