Fig. 13
3.
Remove the bolts securing the gas manifold and
place manifold aside.
Fig. 14
4.
Grasp the burner and lift out.
Fig. 15
5.
Reverse the procedure to install and check for
proper operation.
A.
Ensure the spacers are in place on the
ignition wires. The spacers are intended to
keep the ignition wires from laying flat on the
oven chassis.
B.
Ensure that the bracket on the back of the
burner is inserted into the slot at the rear of
the burner chamber.
NOTE:
Check the flame current by following the
Flame Current Measurement procedures under the
Procedures and Adjustments Section of this manual.
Fig. 16
GAS ORIFICE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the oven.
1.
Remove the lower front cover as outlined under
Covers and Panels.
2.
Remove the bolts securing the gas manifold and
place manifold aside.
Fig. 17
3.
There are two gas orifices on the manifold.
Remove each orifice and replace with the correct
orifice for the given altitude as needed.
Fig. 18
4.
Reverse the procedure to install manifold and
check for proper operation.
GAS SOLENOID VALVE
Disconnect the electrical power to
the machine and follow lockout /
tagout procedures.
Shut off the gas before servicing the oven.
1.
Remove the control panel and the right side
panel as outlined under Covers and Panels.