73
Calibrating electronic/mechanical dual
lever controls
NOTE. Ensure that the levers are parallel with
each other. This is to avoid faults when calibrat-
ing.
NOTE. Calibrate first at the Master Control Sta-
tion followed by the other control stations(s).
1. Set the EDC system to calibration mode accord-
ing to instructions in “Preparations” (see page
71).
2. Move the throttle lever to wide open throttle
(WOT). Hold lever in this position.
Acknowledge the position by pressing in the
green button (Neutral) for at least three seconds.
3. Move lever to idling position. Hold lever in this
position.
Register the position by pressing the green but-
ton. Hold for at least 3 seconds.
4. Move the shift function lever to the position at
which the drive/reverse gear is engaged for
Ahead (forward) movement. Hold lever in this po-
sition.
Register the position by pressing the green but-
ton. Hold for at least 3 seconds.
5. Move the gearshift lever to the position where the
drive/reverse gear is engaged for astern. Hold
the lever in this position.
Register the position by pressing the green but-
ton. Hold for at least 3 seconds.
6. Move the levers to neutral respectively idling po-
sition. Hold the levers in this position.
Register the position by pressing the green but-
ton. Hold for at least 3 seconds.
7. Finish calibration by pressing the green button
(the green and the yellow lamps stop flashing).