![Volvo Penta TAD420VE Workshop Manual Download Page 77](http://html.mh-extra.com/html/volvo-penta/tad420ve/tad420ve_workshop-manual_1048998077.webp)
Technical Data: TD/TAD720-722, TAD730/733, TAD750/760
75
Group 20
Injection pump
(720–733)
Manufacturer ......................................................... Bosch
Designation ........................................................... PF 33 L
Length
A
: .............................................................. 54 mm
(2.12")
Basic measurement length
L
O
: ............................. 143 mm
(5.63")
Min length
L
FB
:
(A/100+143) – 143
........................ >0 mm
Injection pump
(720– 733)
Basic measurements
The injection pumps are made by BOSCH and are of a single
type, that mean one for each cylinder. During the manufacturing
of the injection pumps, it is found that the length will varies from
pump to pump. This is due to manufacturing tolerances and this
is called
A/100
.
The pump length is defined by adding the basic measurement
L
O
with the tolerance
A/100
, that are written on the injection pump
(
L
FB
= L
O
+ A/100
).
Explanation:
L
FB
=
The exact point when injection pumps starts delivering
fuel.
L
O
=
Basic measurement for the injection pumps
A/100 =
Manufacturing tolerances (written on the injection
pump).
Example:
If
L
O
is 117.5 mm and
A/100
is 63.
This gives us the equation:
L
FB
= 143 + 0.63
The total length
L
FB
= 143.63
Injectors
Opening pressure:
TD720GE/ EPA1, TD720VE/EPA1
TAD720VE/EPA1, TAD721VE/EPA1: ................ 25 MPa
(3600 psi)
TAD720GE/COM2, TAD720VE/COM2
TAD721VE/COM2, TAD722VE/COM2
TAD721GE/COM2, TAD722GE/COM2: .............. 27,5 MPa
(4000 psi)
Max pressure:
TD720GE/ EPA1, TAD720GE/EPA1/COM2
TAD720VE/EPA1, TAD721VE/EPA1
TAD721GE/COM2, TAD722GE/COM2: .............. 120 MPa
(17400 psi)
TAD720VE/COM2, TAD721VE/COM2
TAD722VE/COM2: ............................................. 160 MPa
(23200 psi)
Check leakage (for 10 min):
TAD720GE/EPA1, TAD720VE/COM2
TAD721VE/COM2, TAD722VE/COM2: .............. 23 MPa
(3340 psi)
TAD720GE/EPA1, TAD720VE/EPA1
TAD721GE/COM2, TAD722GE/COM2
TAD721VE/EPA1: ............................................. 25,5 MPa
(3700 psi)
Numbers/bore Ø:
TD720GE: .......................................................... 6 x 0.234 mm (6 x 0.00921")
TAD720GE/TD720VE/TAD720VE, EPA 1: ........ 6 x 0.25 mm (6 x 0.00921")
TAD721GE/TAD721VE/TAD722GE, EPA 1: ...... 6 x 0.264 mm (6 x 0.00921")
TAD720VE/TAD721GE/TAD721VE/TAD722GE
COM 2: .............................................................. 6 x 0.236 mm (6 x 0.00921")