Service procedures - lubrication system
Group 22
88
8
7
7
Check the axial play of the pump using a feeler gauge.
Correct play: 0.07–0.15 mm (0.0028–0.0059").
8
Check backlash with a feeler gauge.
Correct play: 0.15–0.30 mm (0.0059–0.0118").
The illustration numbers above refer to the relevant point in the text below.
6
Check the housing for scoring and wear, and also check for
leakage between the bracket and pump housing. In the case
of leakage, the surfaces will be black. The bushings in the
pump housing and bracket must be replaced. The gear
wheels of the pump must be checked concerning wear on
the flanks of the teeth, on the outer diameter and the end fac-
es.