71
Inhibiting
Storage of engine in operating
condition
Service the engine once a month in the following
manner:
1. Crank the engine two times, for 10 seconds each
time, with the starter at intervals of 30 seconds,
with the fuel supply shut off.
2. Start and run the engine under no-load condition
for 5 to l0 minutes.
IMPORTANT! If the engine is fitted with a wet
exhaust system and the exhaust is situated
below the water line the above has to be perfor-
med twice a week (if the exhaust is situated
above the water line, once a week is enough).
Plus d'informations sur : www.dbmoteurs.fr