Rear Panel
The rear panel view shows the inverter’s Cooling fan, DC Battery Terminals,
Fuses, Chassis Ground (some models).
A. Temperature and Load controlled Multi-Speed Cooling Fan
Quiet, efficient fan prolongs equipment service life.
1. Load <40% or inner temperature less than 30
℃
, = fan(s)
don’t run
.
2. Load >40% to <60% = the fan’s rotational speed is 40%
3. Load >60% to <80%, = the fan’s rotational speed is 60%
4. Load >80% to <100% = the fan’s rotational speed is 80%
5. Load @100% = the fan’s rotational speed is 100%
6.Once Inner temperature is more than 45
℃
,
the fan’s rotational speed is 100%.
B.
DC Battery Terminals
Connect the inverter to battery or other power sources.
Negative (-) and Positive (+) DC terminals should be kept insulated to protect
from accidental short circuits.
a)
Connect the red cable to the red post marked (+) on the back of the
inverter. Connect the other end to the positive terminal on the battery
b)
Connect the black cable to the black post marked (-) on the back of the
inverter. Connect the other end to the negative terminal on the battery.
If you connect the cables to the incorrect terminals, you will reverse the
polarity and damage the inverter.
PROHIBITED: REVERSE POLARITY.
DAMAGE CAUSED BY REVERSE POLARITY WILL NOT BE
COVERED BY WARRANTY.