background image

 

16

                                           

 

Appendix II: Recommendations

   

For  correct  operation,  the  battery  voltage  should  be  between  0.9xVnom  and 
1.29xVnom where Vnom is 12V, 24V or 48V depending on model, and must be able 
to  supply  sufficient  current  to  your  inverter.  The  following  table  displays  the 
recommended things(battery cable, Fuse, Battery Capacity) per inverter type : 
 

Inverter type 

Input Voltage 

DC Battery Cable 

Fuse 

Battery Capacity 

300W 

12V 

4

mm²

 (1*Red/1*Black) 

35A*1 

≥50Ah 

24V 

2.5

mm²

 (1*Red/1*Black) 

20A*1 

≥25Ah 

48V 

2.5

mm²

 (1*Red/1*Black) 

10A*1 

≥12Ah 

500W/600W 

12V 

6

mm²

 (1*Red/1*Black) 

35A*4 

≥100Ah 

24V 

4

mm²

 (1*Red/1*Black) 

20A*4 

≥50Ah 

48V 

2.5

mm²

 (1*Red/1*Black) 

10A*4 

≥25Ah 

1000W 

12V 

10

mm²

 (1*Red/1*Black) 

35A*4 

≥160 Ah 

24V 

6

mm²

 (1*Red/1*Black) 

20A*4 

≥80Ah 

48V 

4

mm²

 (1*Red/1*Black) 

10A*4 

≥40Ah 

1500W 

12V 

10

mm²

 (2*Red/2*Black) 

35A*6 

≥250Ah 

24V 

6

mm²

 (2*Red/2*Black) 

20A*6 

≥125Ah 

48V 

4

mm²

 (2*Red/2*Black) 

10A*6 

≥60Ah 

2000W 

12V 

16

mm²

 (2*Red/2*Black) 

35A*8 

≥320Ah 

24V 

10

mm²

 (2*Red/2*Black) 

20A*8 

≥160Ah 

48V 

6

mm²

 (2*Red/2*Black) 

10A*8 

≥80Ah 

2500W 

12V 

16

mm²

 (2*Red/2*Black) 

35A*10 

≥400Ah 

24V 

10

mm²

 (2*Red/2*Black) 

20A*10 

≥200Ah 

48V 

6

mm²

 (2*Red/2*Black) 

10A*10 

≥100Ah 

3000W 

12V 

16

mm²

 (2*Red/2*Black) 

35A*12 

≥480Ah 

24V 

10

mm²

 (2*Red/2*Black) 

20A*12 

≥240Ah 

48V 

6

mm²

 (2*Red/2*Black) 

10A*12 

≥120Ah 

4000W 

12V 

25

mm²

 (2*Red/2*Black) 

35A*12 

≥640Ah 

24V 

16

mm²

 (2*Red/2*Black) 

20A*12 

≥320Ah 

48V 

10

mm²

 (2*Red/2*Black) 

10A*12 

≥160Ah 

5000W 

12V 

35

mm²

 (2*Red/2*Black) 

35A*20 

≥800Ah 

24V 

25

mm²

 (2*Red/2*Black) 

20A*20 

≥400Ah 

48V 

16

mm²

 (2*Red/2*Black) 

10A*20 

≥200Ah 

6000W 

12V 

35

mm²

 (2*Red/2*Black) 

35A*20 

≥960Ah 

24V 

25

mm²

 (2*Red/2*Black) 

20A*20 

≥480Ah 

48V 

16

mm²

 (2*Red/2*Black) 

10A*20 

≥240Ah 

 

 

 

 

Summary of Contents for KS2000P

Page 1: ...put 5V 500mA Optional Variable speed DC fans Controlled by Temperature and Load Protection LED Indicator Audible Alarm 12V or 24V Models Input voltage range 15 25 Output voltage regulation 10 Output w...

Page 2: ...y Bank 7 3 3 Battery wiring examples 7 8 3 4 Placement of the inverter 8 3 5 Mounting position of the inverter 9 3 6 Connections 9 4 Important Safety Instructions 9 10 5 Protection Feature 10 6 Troubl...

Page 3: ...e sine wave inverter With pure sine wave motors start easier and run cooler As well some equipment may only operate properly with a pure sine wave inverter such as laser printers variable speed motors...

Page 4: ...F switch via a communication cable H Hardwire Terminal Block 2500W to 6000W Note When the load current is 10A 2300W You must use the output terminal connection which can be found inside the AC output...

Page 5: ...e is more than 45 the fan s rotational speed is 100 B DC Battery Terminals Connect the inverter to battery or other power sources Negative and Positive DC terminals should be kept insulated to protect...

Page 6: ...or printed on most appliances and equipment In some cases a tool will be rated in amperes To convert from amps to watts multiply Amps x AC voltage Watts Eg 2 0 A x 230 V 460 Watts This formula yields...

Page 7: ...st be capable of delivering to the inverter divide the load watts by ten For example a 500 watt appliance load will need 50 amps at 12 volts DC Using the 500 watts or 50 amps for 10 hours example as a...

Page 8: ...clearance around the unit for air flow Do not place items on or over the inverter during operation Make sure that air is allowed to circulate freely around the unit A fan is helpful in the case where...

Page 9: ...tions 1 Do not attempt to connect the output to any other power source including any AC mains 2 Make sure the opening to the ventilation fan and vent holes are not blocked 3 Avoid pulling on the cords...

Page 10: ...cally shut off Input Over Voltage Protection When input voltage reach 15 5V 0 2V for 12V input inverter 31V 0 4V for 24V input inverter 62V 0 8V for 48V input inverter The Buzzer will sound 4 times an...

Page 11: ...ntact Replace if blown 3 Check that all connections in the battery input circuit are tight Polarity of the input voltage has been reversed that has blown the DC side fuses Note Reverse polarity may ca...

Page 12: ...harger alternator solar charge controller is below 15 V 30V 60VDC 3 Ensure that an un regulated solar panel or wind turbine is not used to charge a battery Buzzer sounds 5 times and Red LED blinks 5 t...

Page 13: ...Open sealed lead acid battery Dimension L W H cm 17 15 5 5 21 15 7 21 15 7 37 5 15 7 2 36 22 9 29 22 9 Packing PCS CTN 12 6 6 4 2 2 KGS CTN 16 5 14 5 15 5 14 5 11 5 13 5 MEAS L W H cm 44 42 32 42 34 4...

Page 14: ...dically with a dry cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals 9 WARRANTY We guarantee this product against defects in materials and wo...

Page 15: ...lash load power is less than 5 of rated power or standby AC ON Solid green Inverter s output is continuous Fault Turns red to show fault refer to Troubleshooting of Inverter Manual Connecting the Comm...

Page 16: ...0 Ah 24V 6mm 1 Red 1 Black 20A 4 80Ah 48V 4mm 1 Red 1 Black 10A 4 40Ah 1500W 12V 10mm 2 Red 2 Black 35A 6 250Ah 24V 6mm 2 Red 2 Black 20A 6 125Ah 48V 4mm 2 Red 2 Black 10A 6 60Ah 2000W 12V 16mm 2 Red...