3.5 Mounting position of the inverter

 

The  inverter  may  be  mounted  on  a  horizontal  or  vertical  service.  Away  from  heat  sensitive 

materials & flammable items.    (Follow All Safety Instructions).   

3.6 Connections 

Follow the connection sequence described below. 

Step 1:

 Ensure that the ON/OFF switch on the Inverter is in the OFF position. If the 

power source is a DC power supply, switch it OFF as well. 

Step 2: 

  Connect inverter to power source.   

Connect  the  DC  cables  to  the  DC  battery  terminals  on  the  rear  panel  of  the  inverter.

 

The  red 

terminal is 

positive (+)

 and the black terminal is negative

 (-). (See Page 5, 2.2B )

 

Step 3

: Connect inverter to appliances.   

Make  sure  the  load  power  within  the  rated  power  of  inverter  and  the  start  power  should  not 

exceed the peak power of the inverter.   

Step 4

: Turn on the inverter 1

st

, then turn on the appliance you want to run. 

If  you  are  operating  several  loads  from  the  power  inverter,  turn  them  on  separately  after  the 

inverter has been turned on. This will ensure that the power inverter does not have to deliver the 

starting currents for all the loads at once. 

4. IMPORTANT SAFETY INSTRUCTIONS 

Incorrect  installation  and  misuse  of  the  inverter  may  result  in  danger  to  the  user  or  hazardous 

conditions.   

1.

 

Do not attempt to connect the output to any other power source, including any AC mains.   

2.

 

Make sure the opening to the ventilation fan and vent holes are not blocked. 

3.

 

Avoid  pulling  on  the  cords  and  cables.  Always  grip  plugs  firmly  when  unplugging  from 

power source and when disconnecting cables. 

4.

 

To  avoid  electrical  hazard,  be  sure  to  unplug  the  inverter  from  its  external  power  source 

before inserting the AC plug. 

5.

 

For  indoor  use  only.  Avoid  exposure  to  external  heat  sources  including  direct/prolonged 

sunlight, dust, corrosive chemicals and moisture. 

6.

 

It is normal for inverters to become warm during use. Avoid touching the device during use   

or positioning near heat-sensitive materials. 

7.

 

Do not drop or subject the inverter to undue shock. 

8.

 

Do not place anything on top of the inverter. 

9.

 

The  use  of  improper  cables,  connectors,  or  accessories  not  supplied  with  this  product 

constitutes misuse and may result in injury or damage. 

10.

 

Do  not  attempt  to  service  or  dissemble.  The  unit  is  not  user-serviceable.  Attempting  to 

disassemble  or  service  the  unit  can  result  in  electrical  hazard,  including  death  from 

High-Voltage  electric  shock!  If  you  experience  problems  with  the  unit,  discontinue  use  and 

contact a competent Technician or the original place of purchase. 

11.

 

When  cleaning  the  inverter,  please  switch  off  power  &  unplug  the  inverter.  Carefully  clean           

with a dry cloth. Do not use wet cloth or cleanser.   

 

Summary of Contents for KS2000P

Page 1: ...put 5V 500mA Optional Variable speed DC fans Controlled by Temperature and Load Protection LED Indicator Audible Alarm 12V or 24V Models Input voltage range 15 25 Output voltage regulation 10 Output w...

Page 2: ...y Bank 7 3 3 Battery wiring examples 7 8 3 4 Placement of the inverter 8 3 5 Mounting position of the inverter 9 3 6 Connections 9 4 Important Safety Instructions 9 10 5 Protection Feature 10 6 Troubl...

Page 3: ...e sine wave inverter With pure sine wave motors start easier and run cooler As well some equipment may only operate properly with a pure sine wave inverter such as laser printers variable speed motors...

Page 4: ...F switch via a communication cable H Hardwire Terminal Block 2500W to 6000W Note When the load current is 10A 2300W You must use the output terminal connection which can be found inside the AC output...

Page 5: ...e is more than 45 the fan s rotational speed is 100 B DC Battery Terminals Connect the inverter to battery or other power sources Negative and Positive DC terminals should be kept insulated to protect...

Page 6: ...or printed on most appliances and equipment In some cases a tool will be rated in amperes To convert from amps to watts multiply Amps x AC voltage Watts Eg 2 0 A x 230 V 460 Watts This formula yields...

Page 7: ...st be capable of delivering to the inverter divide the load watts by ten For example a 500 watt appliance load will need 50 amps at 12 volts DC Using the 500 watts or 50 amps for 10 hours example as a...

Page 8: ...clearance around the unit for air flow Do not place items on or over the inverter during operation Make sure that air is allowed to circulate freely around the unit A fan is helpful in the case where...

Page 9: ...tions 1 Do not attempt to connect the output to any other power source including any AC mains 2 Make sure the opening to the ventilation fan and vent holes are not blocked 3 Avoid pulling on the cords...

Page 10: ...cally shut off Input Over Voltage Protection When input voltage reach 15 5V 0 2V for 12V input inverter 31V 0 4V for 24V input inverter 62V 0 8V for 48V input inverter The Buzzer will sound 4 times an...

Page 11: ...ntact Replace if blown 3 Check that all connections in the battery input circuit are tight Polarity of the input voltage has been reversed that has blown the DC side fuses Note Reverse polarity may ca...

Page 12: ...harger alternator solar charge controller is below 15 V 30V 60VDC 3 Ensure that an un regulated solar panel or wind turbine is not used to charge a battery Buzzer sounds 5 times and Red LED blinks 5 t...

Page 13: ...Open sealed lead acid battery Dimension L W H cm 17 15 5 5 21 15 7 21 15 7 37 5 15 7 2 36 22 9 29 22 9 Packing PCS CTN 12 6 6 4 2 2 KGS CTN 16 5 14 5 15 5 14 5 11 5 13 5 MEAS L W H cm 44 42 32 42 34 4...

Page 14: ...dically with a dry cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals 9 WARRANTY We guarantee this product against defects in materials and wo...

Page 15: ...lash load power is less than 5 of rated power or standby AC ON Solid green Inverter s output is continuous Fault Turns red to show fault refer to Troubleshooting of Inverter Manual Connecting the Comm...

Page 16: ...0 Ah 24V 6mm 1 Red 1 Black 20A 4 80Ah 48V 4mm 1 Red 1 Black 10A 4 40Ah 1500W 12V 10mm 2 Red 2 Black 35A 6 250Ah 24V 6mm 2 Red 2 Black 20A 6 125Ah 48V 4mm 2 Red 2 Black 10A 6 60Ah 2000W 12V 16mm 2 Red...

Reviews: