S E C T I O N 4 - T R O U B L E S H O O T I N G
CAFFÈ MIO – OPERATION AND SERVICE
Page 38 of 110
T r o u b l e s h o o t i n g
Brewer Overflow
►
Water setting may be too high – reduce the water setting.
►
Bottom pause setting may need to be increased.
►
Coffee setting may be too high – reduce the coffee setting.
►
Coffee may be stale or not within specifications – replace coffee.
►
Water temperature may be too high – reduce the temperature.
►
Screen assembly may be dirty and clogged – clean or replace the brewer screen
assembly
(P/N - K310306)
.
►
Screen assembly may be damaged – replace screen assembly
(P/N - K310306)
.
►
Brew chamber may be cracked creating a vacuum loss – replace chamber
(P/N -
M044065)
.
►
Cylinder may be scored or cracked creating a vacuum loss – replace cylinder
(P/N -
M044071)
.
►
Teflon seal on piston may be worn – replace Teflon seal
(P/N - K110174)
.
Water Tank
Boiling /Overfilling
►
Clean and dry the overflow cup.
►
The equipment may have been moved or bumped.
►
If water tank is overfilling, check the following;
o
Water level probes may require cleaning.
o
Water level probe harness may be defective – replace the probe harness.
o
Inlet valve may be leaking – replace inlet valve
(P/N - E310018)
.
►
If water tank is boiling over, check the following;
o
Water temperature setting may be too high – reduce temperature setting.
o
Temperature probe may be defective – replace the probe
(P/N - M210220)
.
o
Components inside water tank may be covered with scale – delime water tank.
o
Verify the wiring and connections to the water tank.
Not Heating
►
The overflow cup may be full of liquid – clean and dry the overflow cup.
►
15 amp fuse may be blown – replace the fuse
(P/N - M018046)
.
►
Thermal cut-off switch may be tripped – press the small button in the center of the
thermal cutoff switch to reset.
►
If thermal cutoff switch trips with a full water tank, replace the thermal cutoff switch
(P/N - A210087)
.
►
Verify the wiring and connections to the water tank.
►
Check for power to the heater element. If power is present, replace the heater
element
(P/N - E310016)
.
►
The heater relay may be defective – replace the heater relay
(P/N - M018R08)
.
►
Temperature probe may be defective – replace the temperature probe
(P/N -