Min. power on voltage (A)
Min. operating voltage (B)
Disabled (default)
9
9
12V
11.5~12.5, default 12
10.5~11.5, default 11
24V
23.5~24.5, default 24
22.5~23.5, default 23
36V
35~37, default 36
34~35, default 34.5
48V
47~49, default 48
46~47, default 46.5
To power up and power down,
On the initial configuration:
The NVR is started when the vehicle ignition is started sensing the voltage. The NVR
supports configurable power ON/OFF delay time. Low power protection is also supported.
See page 125 for the delayed ON/OFF configuration (see Settings > System > Power
After the initial connection,
When the vehicle engine stops, the system should start flushing the cached contents in
system memory and gracefully shut down. The NVR can be configured to power down later
than the engine stop using the battery power.
Press the Reset button for longer than
5
seconds can restore system defaults.
Power Up and Power Down
7
The NVR supports low battery power detection and automatic power-down when voltage drops
below a configurable threshold.
See page 125 for information about Power management.