A/A DC INVERTER U-MATCH AIR CONDITIONERS CONTROL
35
4.2.2 Instruction to Function of Buttons
No.
Description
Function of Button
1 Enter/cancel
(
1
)
Function selection and canceling;
(
2
)
Press it for 5s to enquiry the outdoor ambient temperature.
2
▲
6
▼
(
1
)
Running temperature setting of indoor unit, range :16
~
30
℃
(
2
)
Timer setting, range:0.5-24hr
(
3
)
Switchover between quiet/auto quiet
3
Fan
Setting of high/middle/low/auto fan speed
4
Mode
Setting of cooling/heating/fan/dry mode of indoor unit
5 Function
Switch over among these functions of
air/sleep/turbo/save/e-heater/blow /quiet
7 Timer
Timer
setting
8
On/off
Turn on/off indoor unit
4 Mode
and
2
▲
Memory function
Press Mode and
▲
for 5s under off state of the unit to enter/cancel key
memory function (If memory is set, indoor unit will resume original
setting state after power failure and then power recovery. If not, indoor
unit is defaulted to be off after power recovery. Memory function is
defaulted to be off before outgoing.)
2
▲
and
6
▼
Lock
Upon startup of the unit without malfunction or under off state of the unit,
press
▲
▼
key at the same time for 5s in to lock state. In this case, any
other buttons won’t respond the press. Repress
▲
▼
key for 5s to quit
lock state.
4 Mode
and
5 Function
Enquiry and setting of
address of wired
controller
Under the off-state of the unit, press Mode/Function button for 5
seconds to set the address.
5 Function
And
7Timer
Setting Ambient
Temperature Sensor
and three Grades of
Speed for Indoor Fan
Under off state of the unit, press Function and Timer buttons
continuously for 5s to go to the debugging menu. Press Mode button to
adjust the setting items and
▲
or
▼
button to set the actual value.
5 Function
and
6
▼
Enquiry of Historical
Errors
Continuously press Function and
▼
buttons for 5s to go to the enquiry
state. In this state, press Enter/Cancel button to quit, or it will
automatically quit after there is not any operation of button in 30min
Summary of Contents for ACP-12CC35GECI
Page 2: ......
Page 3: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 1 PRODUCT ...
Page 15: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 22 CONTROL ...
Page 17: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation ...
Page 52: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 59 5 3 7 Dimensions ...
Page 53: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 60 INSTALLATION ...
Page 76: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 99 MAINTENANCE ...
Page 95: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 118 IPM module protection ...
Page 96: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 119 DC busbar overvoltage protection ...
Page 97: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 120 DC busbar undervoltage protection ...
Page 98: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 121 Abnormal noise from PFC inductor ...
Page 99: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 122 Radiator overheat protection ...
Page 100: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 123 Tripping ...
Page 176: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 242 Model ACP 12CC35GECI Exploded View ...
Page 178: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 244 Model ACP 18CC50GECI Exploded View ...
Page 182: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 249 Model ACP 36CC100GECI Exploded View ...
Page 188: ......
Page 189: ......
Page 190: ......