A/A DC INVERTER U-MATCH AIR CONDITIONERS MAINTENANCE
211
Remove
panel parts
●
Remove the screws
shown by the arrow in
the graph with
screwdriver (two on
both right and left and
4 in the front) and
then remove the
panel parts.
Remove sub-assy of electric box
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during
disassembly, especially the components inside the box in case of water and hit.
Step Illustration
Handling
Instruction
1. Remove
electric box
cover
●
Remove 3 screws
as shown by the
arrow in the graph on
left and remove the
electric box cover.
Remove air deflecting plate modules
Remark: Make sure the power supply is cut off before disassembling and protect all the parts during
disassembly, especially the joints of the air deflecting plate.
Step Illustration Handling
Instruction
Remove
sub-assy of
air deflecting
plate
●
Remove the air
deflecting plates
from the air
deflecting plate
support assembly,
and then remove
both ends from the
air sweeping motor
joint. (As is shown
in the graph, arrow
represents the
support assembly
and circle the air
sweeping motor
joint.)
Remove water-containing plate modules
Remark: Make sure the power supply is cut off before disassembling and protect all the parts during
disassembly.
Step Illustration Handling
Instruction
Remove
water-containin
g plate
modules
●
Remove the
water-containing
plate modules.
Remove evaporator components
Remark: Make sure that the power supply is cut off and protect the copper tube and aluminum fin. If the
time for disassembly shall be long, seal the copper tube.
Step Illustration
Handling
Summary of Contents for ACP-12CC35GECI
Page 2: ......
Page 3: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 1 PRODUCT ...
Page 15: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 22 CONTROL ...
Page 17: ...A A DC INVERTER U MATCH AIR CONDITIONERS CONTROL 24 1 2 Heating Operation ...
Page 52: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 59 5 3 7 Dimensions ...
Page 53: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 60 INSTALLATION ...
Page 76: ...GREE COMMERCIAL AIR CONDITION A A DC INVERTER U MATCH AIR CONDITIONERS 99 MAINTENANCE ...
Page 95: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 118 IPM module protection ...
Page 96: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 119 DC busbar overvoltage protection ...
Page 97: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 120 DC busbar undervoltage protection ...
Page 98: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 121 Abnormal noise from PFC inductor ...
Page 99: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 122 Radiator overheat protection ...
Page 100: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 123 Tripping ...
Page 176: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 242 Model ACP 12CC35GECI Exploded View ...
Page 178: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 244 Model ACP 18CC50GECI Exploded View ...
Page 182: ...A A DC INVERTER U MATCH AIR CONDITIONERS MAINTENANCE 249 Model ACP 36CC100GECI Exploded View ...
Page 188: ......
Page 189: ......
Page 190: ......