5
ENGLISH
Draughts or other air flows may affect the air
humidity indications in the room.
CONTROL PANEL (2)
«SWITCH ON» Button (14)
You can switch the unit on and off by one pressing
of the button.
«IONIZATION» Button (15)
You can switch the ionization mode on and off by
one pressing of the button (15) «IONIZATION».
«MAX/MIN» Button (16)
Select mist release intensity by pressing
consequently the button (16) «MAX/MIN»:
«1» - low intensity,
«2»- medium intensity,
«3»- high intensity.
«HUMIDIFICATION» Button (17)
Set the desired relative humidity level in the
room. Once the desired relative humidity level is
reached, the unit will be switched off, when the
relative humidity level decreases, the unit will
switch on.
Consequently
press
the
button
(17)
«HUMIDIFICATION» to set the relative humidity
level from 45% to 75% with a step 5%.
To cancel the maintenance of the relative
humidity level consequently press the button (17)
«HUMIDIFICATION» till the symbol «Co» appears
on the display (1), the unit will be operating
constantly.
«TIMER» timer on button (18)
You can set the switch off time. To do this,
consequently press or hold the button (18)
«TIMER». The timer is set in the range from 1 to
12 hours with 1 hour step.
To switch the timer off consequently press the
button (18) «TIMER» until the symbol «- - H»
appears on the display.
Low water level indication
When the water tank (8) becomes empty, the unit
will be switched off, you will hear a sound signal,
and the indicator will light up red in the right part
of the display. Switch the unit off using the button
(14) «SWITCHING ON» and unplug it, remove
the nozzle (11) and the water tank. Fill the tank
with water (see the chapter «Operation»). Install
the filled tank and then the nozzle back to their
places. Switch the unit on.
Water tank illumination (5)
The illumination (5) lights up when the unit is
plugged in. The illumination allows to check the
water level in the tank (8).
CLEANING AND CARE
Warning! Always switch the unit off and
unplug it before cleaning.
Hard water causes appearance of mineral scale
in the process chamber (4) and in the water tank
(8) that leads to improper operation of the unit.
To avoid it:
– use filtered, boiled and settled water. If tap
water is hard, it is recommended to mix it with
distilled water in proportion 1:1. If tap water is
too hard, mix it with distilled water in propor-
tion 1:2 or use distilled water only.
– change water in the water tank (8) every day.
Weekly care
– Thoroughly wash the process chamber (4)
and the water tank (8) with neutral detergent
solution.
– To clean the sprayer add 5-10 drops of deter-
gent on it and wait for 2-5 minutes. Remove
the deposit from the sprayer surface with a
brush (13).
Note:
As a cleaning agent for the sprayer you can
use scale removers for electric kettles.
Do not immerse the unit body into water or
other liquids.
Cleaning of the cartridge filter (7)
– The cartridge filter (7) prevents generation
of bacteria, softens the water and removes
unpleasant smells.
– Clean the cartridge filter after passing of
about 1000 l of water through it, and if using
hard water or a white deposit appears on the
furniture, more often.
– Take the handle (9) and remove the water
tank (8) from the unit body. Remove the noz-
zle (11).
– Turn over the tank, open the lid (6) with the
cartridge filter rotating it counterclockwise.
Remove the lid (6) from the cartridge filter.
VT-1769.indd 5
05.12.2013 10:54:54
Summary of Contents for VT-1769 W
Page 1: ...1 3 7 12 17 21 25 28 32 36 Air humidifier VT 1769 W VT 1769 indd 1 05 12 2013 10 54 53...
Page 2: ...VT 1769 indd 2 05 12 2013 10 54 54...
Page 13: ...13 8 8 10 40 C 80 40 11 9 8 6 LOOSEN 6 FASTEN VT 1769 indd 13 05 12 2013 10 54 55...
Page 16: ...16 1 1 220 240 50 30 5 300 50 2 3 38 7 1070 VT 1769 indd 16 05 12 2013 10 54 55...
Page 35: ...35 1 1 220 240 50 30 5 300 50 2 3 2 12 50 2 VT 1769 indd 35 05 12 2013 10 54 56...
Page 40: ...2013 GOLDER ELECTRONICS LLC 2013 VT 1769 indd 40 05 12 2013 10 54 57...