27
• SYSTEM SETUP
SYSTEM SETUP
MOTOR SETUP
PASSWORD EDIT
ORIGIN CHECK
CALIBRATION : ON
PASSWORD ENABLE : OFF
MENU TIMEOUT : OFF
DOME ANSWER : OFF
PRESET FOCUS : AUTO
SAVE AND EXIT(ESC TO CANCEL)
CALIBRATION
ON (Auto origin check), OFF
PASSWORD ENABLE
ON (requires the password to enter menu), OFF
MENU TIMEOUT
ON (5 minutes), OFF (always menu display)
DOME ANSWER
ON, OFF (no acknowledge command from the dome)
This option is helpful to escape the collision of the command using some DVR.
PRESET FOCUS
AUTO, MANUAL, ONE PUSH
This option set the default mode of the focus when you save the Preset.
MOTOR SETUP
Motor Setup menu provides the pan and tilt speed of a camera. User can set the desired
speed with pressing the
Right
or
Left
key.
MOTOR SETUP
PROPORTIONAL P/T : ON
P/T MODE : NORMAL
SLOW PAN MAX : 40
SLOW TILT MAX : 40
NORMAL PAN MAX : 90
NORMAL TILT MAX : 90
TURBO PAN MAX : 360
TURBO TILT MAX : 100
SAVE AND EXIT(ESC TO CANCEL)
PROPOTIONAL P/T
ON, OFF
P/T MODE
SLOW, NORMAL, TURBO
SLOW PAN Maximum speed
19
~ 90
/second
SLOW TILT Maximum speed
19
~ 90
/second
NORMAL PAN Maximum speed
40
~ 360
/second
NORMAL TILT Maximum speed
40
~ 200
/second
TURBO PAN Maximum speed
200
~ 380
/second
TURBO TILT Maximum speed
90
~ 300
/second