3.10 Dome Communication
To prevent damage, each dome camera must have a unique address (ID).
The factory default setting is 1.
DOME COMMUNICATION
$
DOME ID : 0001
PROTOCOL : AUTO
BAUDRATE : 9600
PARITY : NONE
TERMINATION : OFF
SAVE AND EXIT(ESC TO CANCEL)
DOME ID
1 ~ 3999
PROTOCOL
AUTO, F2/F2E, PELCO-PD
BAUDRATE
2400, 4800, 9600, 19200, 38400 bps
PARITY
NONE, EVEN, ODD
TERMINATION (RS-485)
OFF, ON
The device which is connected at end of line, whether it is a dome camera or keyboard, must
have the cable for communication terminated by setting the appropriate DIP switch. Without
proper termination, there is potential for control signal errors. Total length of the cable for
communication should not exceed 4000 ft (1.2 km).