Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Copyright ©
Version 1.4
(view of rear of controller EC200)
System plugs (15)
Pin
Type
Area
Item
O1C Collector*
max. 30V/10mA
Dosing
(Dosing running=transistor interconnected)
O1E Emitter*
O2C Collector*
Remote mode
(local operating mode or no ecoRemote
connected=transistor interconnected)
O2E Emitter*
O3C Collector*
not set
O3E Emitter*
ISS
Make contact
0-24V
ext. Start (0V= Stop, 24V=Start)
IA1
0-10V
Analogue input 1 (voltage)
IA2
4-20mA
Analogue input 2 (current)
GND GND analogue
GND
GND sensor
GND
* galvanically separated
Foot switch (18)
1 Contact via make contacts
2 Contact via make contacts
3 not set
Matching plug Part No. 20055