Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Version 1.4
Copyright ©
5.10.10 Tolerance value primary pressure monitoring
• Press
PRG
,
system selection menu
,
display 2 appears.
• Select
Administration
, display 25 appears.
Displa
y 2
• Select
Inp. pressure tolerance
, display 29 appears.
Displa
y 25
• In the
pressure tolerance
input dialog, enter the tolerance
and confirm with
OK
, display 25
appears.
Displ
ay 29
5.10.11 Password protection
The password protection blocks access to the settings of the controller and all
function keys. Dosing is possible via a foot switch (optional) and an external signal
(system plug). The most recently selected dosing program is always run and shown
on the display.
Setting range for the password: 0000 to 9999
Time of the automatic blocking after the last input: 30 seconds.
Turning on password protection
• Press the
PRG
key,
system selection menu
, display 2
appears.
• Select and confirm
Administration
, the
Administration
menu, display 25 appears.
Di
sp
lay 2
Calibration auto
Calibration manuell
Service
Flush manually A
Flush manually B
Administration
Programs
10 47h
Fr 18.03.11
Accept with OK
Esc
Tol. of input pressure
Tolerance
±
OK
0.3 Bar
Calibration auto
Calibration manuell
Service
Flush manually A
Flush manually B
Administration
Programs
10 47h
Fr 18.03.11