Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Copyright ©
Version 1.4
• Select
Password protection
, display 41 appears.
D
is
pl
a
y 25
• Press the
Navi wheel
, display
On
, changes to
Off
,
Protection active
appears in the status bar.
• Select and confirm the password (code).
• Set the password by turning* the
Navi wheel
.
• Press the
OK
button and confirm, password protection has
been activated.
Display 41
* Dynamic behaviour: The faster it is turned, the quicker the range of numbers
changes.
Note:
If no further buttons are pressed, the password protection blocks the controller
after 30 seconds.
Releasing the controller
(if password protection has been activated)
The start screen is shown when it is in the blocked state.
Display 42 appears if a button is pressed.
• Select the correct password by turning the
Navi wheel
and
confirm it by pressing, then the start screen appears.
Displa
y 42
Note:
If no further buttons are pressed, the password protection blocks the controller
after 30 seconds.
Turning off password protection
Release the controller as described above.
• Press the
PRG
key,
system selection menu
,
display 2 appears.
• Select and confirm
Administration
, the
Administration
menu, display 25 appears.
Displa
y 2
Calibration auto
Calibration manuell
Service
Flush manually A
Flush manually B
Administration
Programs
10 47h