Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Copyright ©
Version 1.4
Dosing by means of an external controller
As in the case of
dosing with the foot switch
, but the triggering and termination of the
dosing are done by supplying an electrical signal. See 8.3, Interface description, page 36.
Notice:
If a memory card is being used, press the foot switch briefly to load the saved and
most recently run program and to display it on the screen. Press the foot switch once
again to start the dosing. It behaves in exactly the same way with an external signal.
5.9
Calibrating
Preparation
• Mount the calibration adapter (see 2K-dispenser operating manual).
• Connect to the controller the 2K-dispenser that has been made ready for operation
and bled.
Caution:
The 2K-dispenser lead (connector 16, Chapter 5.2, Connectionson page
11) may only be connected and disconnected when the power supply is isolated. The
electronics in the drive motor could be damaged if this precaution is not taken.
• Keep at hand a suitable vessel (calibration vessel) to catch and measure the quantity
required for calibration.
5.9.1
Automatic calibration
Notice:
During the calibration operation the Dosing system cannot be operated by
either the foot switch or an external control signal.
• Press
PRG
,
system selection menu
,
display 2 appears.
• Select
Calibration auto
• Select motor
A
or
B
, menu
Calibration
auto
, display 15
appears.
Display 2
Select whether the calibration is to be done with quantity
unit
ml
(
µl
)
or
g
(mg)
*
and confirm this, the set quantity can
be set as desired.
Display 15
• Set and confirm the set quantity.
The value preset in the Dosing system is to be regarded as the ideal value.
• Position the calibration vessel under the calibration adapter of the 2K-dispenser.
Calibration auto
Calibration manuell
Service
Flush manually A
Flush manually B
Administration
Programs
10 47h
Fr 18.03.11
Press Start
Esc
Calibration auto
Motor A
ml
Desired qty
Actual qty
ml
ml
00.500ml
00.000ml