GW6600 Series User manual
Issue: 1.7
Page 409 of 519
38.2.2
Configuring keepalive heartbeat using the web interface
Select Services -> Monitor. The Monitor Keepalive & ISAD page appears.
The keepalive heartbeat is configured under the Basic Settings section.
A single instance keepalive can be configured to multiple monitor address using the
same reference, heartbeat interval and other options. Or alternatively multiple keepalive
instances can be configured with unique options.
Figure 194: The Monitor & ISAD keepalive page
38.2.2.1
Basic settings
Web Field/UCI/Package Option
Description
Web: Enabled
UCI: monitor.@keepalive[0].enabled
Opt: Enabled
Enables Monitor to send heartbeats to the router.
0
Disabled.
1
Enabled.
Web: Dev Reference
UCI:
monitor.@keepalive[0].dev_reference
Opt: dev_reference
Sets a unique identification for this device known to Monitor.
Web: Monitor Address
UCI: monitor.@keepalive[0].monitor_ip
Opt: list monitor_ip
Defines the IP address of Monitor. It is possible to specify
multiple addresses to which SNMP heartbeat traps will be sent.
To configure via UCI use a space separator. Example:
monitor.@keepalive[0].monitor_ip=1.1.1.1 2.2.2.2
Web: Monitor Heartbeat Interval
UCI: monitor.@keepalive[0].interval_min
Opt: interval_min
Specifies the interval, in minutes, at which traps are sent.
1
Trap set every 1 minute.
Range
Web: SNMP Protcol Version
UCI:
monitor.@keepalive[0].snmp_version
Opt: snmp_version
Specifies what SNMP version is sent to remote Manager.
1
snmp version 1
2c
SNMP version 2c
3
SNMP version 3
Table 144: Information table for Monitor & ISAD basic configuration