24: Automatic operator selection
_______________________________________________________________________________________________________
_______________________________________________________________________________________________________
© Virtual Access 2018
GW6600 Series User manual
Issue: 1.7
Page 252 of 519
Web: Signal Test
UCI: multiwan.[..x..].signal_test
Opt: signal_test
Defines script to test various signal characteristics in multiwan
signal test. For example:
option signal_test '(tech == 0) then (sig_dbm > -70) else
(rscp_dbm > -105 and ecio_db > -15)'
This states that when technology is GSM a health fail is
determined when signal strength is less than -70dBm. When
technology is not GSM a health fail occurs when either rscp_dbm
falls below -105dBm or ecio_db falls below -15dB.
Tech values are:
0
GSM
1
GSM Compact
2
UTRAN
3
GSM w/EGPRS
4
UTRAN w/HSPDA
5
UTRAN w/HSUPA
6
UTRAN w/HSUPA and HSDPA
7
E-UTRAN
Table 89: Information table for Multi-WAN page
Click Save.
24.2.2
Set options for automatically created interfaces (failover)
From the top menu on the web interface page, select Services ->Mobile Manager. The
Mobile Manager page appears.
There are four sections in the mobile manager page:
Section
Description
Basic settings
Enable SMS, configure SIM pin code, select roaming SIM, collect ICCCIDs and set
IMSI.
Advanced
Configure advanced options such as collect ICCID’s and temperature polling interval
CDMA*
CDMA configuration
Callers
Configure callers that can use SMS.
Roaming Interface
Template
Configure Preferred Roaming List options
*Option available only for Telit CE910-SL module.