LAMINATING &
UNWINDING MODULE
WASTE REMOVING &
REWINDING MODULE
MEDIA PATH
ULTRASONIC SENSOR CALIBRATION
LAMINATING & UNWINDING
MODULE
1. Turn OFF the main power “ON-OFF”
red switch.
2. Raise up the tension arm up to the
desired position (generally it is in the
middle of the range). In that position,
the system will reach the maximum
unwinding’s speed. The longer your
label will be, the lower tension arm
position requires to be set.
3. Holding the tension arm idle at
the desired position, keep pushed
“
Forward Media
” button, in the mean
time turn ON the main power red
switch and wait until the yellow led will
have flashed 3 times and an acoustic
beep signal will have been issued.
4. The ultrasonic sensor has been
calibrated and ready to be operative.
WASTE
MATRIX
FINISHED
ROLL
LAMINATION
ROLL
PRINTED
ROLL
WASTE REMOVING & REWINDING
MODULE
1. Keeping ON the main power “ON-
OFF” red switch. Turn “OFF” the
module (both leds are off).
1. Raise up the tension arm up to the
desired position (generally it is in the
middle of the range). That point will
determinate the tension arm working
range from the bottom position. The
longer your label will be, the lower
tension arm position requires to be set.
2. Holding the tension arm idle at the
desired position, using a paper clip,
keep pushed the button into the small
hole until the yellow led will have
flashed 3 times.
3. The ultrasonic sensor has been
calibrated and ready to be operative.
26